|
Number |
Title |
Amendment |
Context |
|
|
BS 5588 |
Fire precautions in the design, construction and use of buildings - |
|||
|
: Part 1: 1990 |
- Code of practice for residential buildings |
AMD 7840 |
(E8.11) |
|
|
: Part 4: 1978 |
- Code of practice for smoke control in protected escape routes using pressurization |
AMD 5377 |
(D2.1), (E5.1) |
|
|
: Part 5: 1991 |
- Code of practice for fire-fighting stairs and lifts |
AMD 7196 |
(E9.4), (E9.7-E9.9) |
|
|
: Part 6: 1991 |
- Code of practice for places of assembly |
(E8.20-E8.21) |
||
|
: Part 8: 1999 |
- Code of practice for means of escape for disabled people |
(E3.4) |
||
|
: Part 9: 1989 |
- Code of practice for ventilation and air conditioning ductwork |
(D5.1) (E7.6) |
||
|
BS 5615 |
: 1985 |
Specification for insulating jackets for domestic hot water storage cylinders |
(J3.4) |
|
|
BS 5617 |
: 1985 (1996) |
Specification for urea-formaldehyde (UF) foam systems suitable for thermal insulation of cavity walls with masonry or concrete inner and outer leaves |
(G3.1) |
|
|
BS 5618 |
: 1985 (1996) |
Code of practice for thermal insulation of cavity walls (with masonry or concrete inner and outer leaves) by filling with urea-formaldehyde(UF) foam systems |
AMD 6262 AMD 7114 |
(G3.1) |
|
BS 5628 |
Code of practice for use of masonry - |
|||
|
: Part 1: 1992 |
- Structural use of unreinforced masonry |
AMD 7745 |
(C2.1), (C3.1) |
|
|
: Part 2: 1995 |
- Structural use of reinforced and prestressed masonry |
(C2.1), (C3.1) |
||
|
: Part 3: 1985 |
- Materials and components, design and workmanship |
AMD 4974 |
(C2.1) (G3.1) (H2.1-H2.3) |
|
|
BS 5720 |
: 1979 |
Code of practice for mechanical ventilation and air conditioning in buildings |
(K2.1), (K4.9) |
|
|
BS 5776 |
: 1996 |
Specification for powered stairlifts |
(S2.7) |
|
|
BS 5810 |
: 1979 |
Code of practice for access for the disabled to buildings |
(E3.4) |
|
|
BS 5839 |
Fire detection and alarm systems for buildings - |
|||
|
: Part 1: 1988 |
- Code of practice for system design, installation and servicing |
AMD 6317 AMD 6874 AMD 9257 |
(E5.7) (E10.1E10.2) |
|
|
: Part 2: 1983 |
- Specification for manual call points |
AMD 4685 AMD 5085 |
(E10.2) |
|
|
: Part 3: 1988 |
- Specification for automatic release mechanisms for certain fire protection equipment |
(E5.7) |
||
|
: Part 6: 1995 |
- Code of practice for the design and installation of fire detection and alarm systems in dwellings |
AMD 9135 |
(E10.1) |
|
|
: Part 8: 1998 |
- Code of practice for the design, installation and servicing of voice alarm systems |
(E10.2) |
||
|
BS 5864 |
: 1989 |
Specification for installation in domestic premises of gas-fired ducted-air heaters of rated input not exceeding 60 kW |
AMD 8130 |
(J5.1) |
|
BS 5867 |
Specification for fabrics for curtains and drapes - |
|||
|
: Part 2: 1980 (1993) |
- Flammability requirements |
AMD 4319 |
(E6.1) |
|
|
BS 5871 |
Specification for the installation of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances |
|||
|
: Part 1: 1991 |
- Gas fires, convector heaters and fire/back boilers(1st, 2nd and 3rd family gases) |
(F6.16) |
||
|
: Part 2: 1991 |
- Inset live fuel effect gas fires of heat input not exceeding 15kW (2nd and 3rd family gases) |
(F6.3), (F6.7) (F6.16) |
||
|
: Part 3: 1991 |
- Decorative fuel effect gas appliances of heat input not exceeding 15kW (2nd and 3rd family gases) |
AMD 7033 |
(F6.3), (F6.6) (F6.7), (F6.16) |
|
|
BS 5906 |
: 1980 (1987) |
Code of practice for storage and on-site treatment of solid waste from buildings |
(R2.1), (R2.3), (R2.4), (R2.6), (R2.7), (R2.9) |
|
|
BS 5925 |
: 1991 (1995) |
Code of practice for ventilation principles and designing for natural ventilation |
AMD 8930 |
(K2.1) |
|
BS 5930 |
: 1981 |
Code of practice for site investigations |
G Appendix |
|
|
BS 5950 |
Structural use of steelwork in building - |
|||
|
: Part 1: 1990 |
- Code of practice for design in simple and continuous construction: hot rolled sections |
AMD 6972 |
(C2.1), (C3.1) |
|
|
: Part 2: 1992 |
- Specification for materials, fabrication and erection: hot rolled sections |
AMD 7766 |
(C2.1) |
|
|
: Part 3: Section 3.1: 1990 |
- Design in composite construction - Code of practice for design of simple and continuous composite beams |
(C2.1) |
||
|
: Part 4: 1994 |
- Code of practice for design of composite slabs with profiled steel sheeting |
(C2.1) |
||
|
: Part 5: 1987 |
- Code of practice for design of cold formed sections |
AMD 5957 |
(C2.1) |
|
|
: Part 6: 1995 |
- Code of practice for design of light gauge profiled steel sheeting |
(C2.1) |
||
|
: Part 7: 1992 |
- Specification for materials and workmanship: cold-formed sections |
(C2.1) |
||
|
: Part 8: 1990 |
- Code of practice for fire resistant design |
AMD 8858 |
(C2.1), D Appendix |
|
|
BS 6073 |
Precast concrete masonry units - |
|||
|
: Part 1: 1981 |
- Specification for precast concrete masonry units |
AMD 3944 AMD 4462 |
D Appendix |
|
|
BS 6229 |
: 1982 |
Code of practice for flat roofs with continuously supported coverings |
(G3.1) |
|
|
BS 6262 |
: 1982 |
Code of practice for glazing for buildings |
AMD 4063 AMD 4582 AMD 8279 |
(P2.2) |
|
BS 6262 |
Glazing for buildings - |
|||
|
: Part 4: 1994 |
- Code of practice for safety. Human impact |
(P2.2) |
||
|
BS 6283 |
Safety devices for use in hot water systems - |
|||
|
: Part 2: 1991 |
- Specification for temperature relief valves for pressures from 1 bar to 10 bar |
(P3.1) |
||
|
: Part 3: 1991 |
- Specification for combined temperature and pressure relief valves for pressures from1 bar to 10 bar |
(P3.1) |
||
|
BS 6297 |
: 1983 |
Code of practice for design and installation of small sewage treatment works and cesspools |
AMD 6150 |
(M2.5) |
|
BS 6367 |
: 1983 |
Code of practice for drainage of roofs and paved areas |
AMD 4444 |
(M2.1) |
|
BS 6387 |
: 1994 |
Specification for performance requirements for cables required to maintain circuit integrity under fire conditions |
(D7.5) |
|
|
BS 6399 |
Loading for buildings - |
|||
|
: Part 1: 1996 |
- Code of practice for dead and imposed loads |
(C2.1), (S4.3) (S4.5) |
||
|
: Part 2: 1997 |
- Code of practice for wind loads |
(C2.1) |
||
|
: Part 3: 1988 |
- Code of practice for imposed roof loads |
AMD 6033 AMD 9187 AMD 9452 |
(C2.1) |
|
|
BS 6440 |
: 1983 |
Code of practice for powered lifting platforms for use by disabled persons |
(S2.7) |
|
|
BS 6461 |
Installation of chimneys and flues for domestic appliances burning solid fuel (including wood and peat) - |
|||
|
: Part 1: 1984 |
- Code of practice for masonry chimneys and flue pipes |
AMD 5649 |
(F3.5), (F3.8) (F4.11) |
|
|
BS 6465 |
Sanitary installations - |
|||
|
: Part 1: 1994 |
- Code of practice for scale of provision, selection and installation of sanitary appliances |
(M3.1) |
||
|
BS 6676 |
Thermal insulation of cavity walls using man-made mineral fibre batts (slabs) - |
|||
|
: Part 1: 1986 (1994) |
- Specification for man-made mineral fibre batts (slabs) |
(G3.1) |
||
|
: Part 2: 1986 (1994) |
- Code of practice for installation of batts (slabs) filling the cavity |
(G3.1) |
||
|
BS 6677 |
Clay and calcium silicate pavers for flexible pavements - |
|||
|
: Part 1: 1986 (1997) |
- Specification for pavers |
(Q2.4), (S2.3) |
||
|
: Part 2: 1986 (1997) |
- Code of practice for design of lightly trafficked pavements |
(Q2.4), (S2.3) |
||
|
BS 6700 |
: 1997 |
Specification for design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages |
(P3.1) |
|
|
BS 6717 |
Precast concrete paving blocks - |
|||
|
: Part 1: 1993 |
- Specification for paving blocks |
(Q2.4), (S2.3) |
||
|
BS 6880 |
Code of practice for low temperature hot water heating systems of output greater than 45 kW - |
|||
|
: Part 1: 1988 |
- Fundamental and design considerations |
(J5.1) |
||
|
BS 6915 |
: 1988 |
Specification for design and construction of fully supported lead sheet roof and wall coverings |
(G3.1) |
|
|
BS 6999 |
: 1989 (1996) |
Specification for vitreous-enamelled low-carbon-steel flue pipes, other components and accessories for solid-fuel-burning appliances with a rated output of 45kW |
AMD 8949 |
(F4.12) |
|
BS 7036 |
: 1996 (Parts 1 to 5) |
Code of practice for safety at powered doors for pedestrian use |
(E3.4) |
|
|
BS 7206 |
:1990 |
Specification for unvented hot water storage units and packages |
AMD 9343 |
(P3.1) |
|
BS 7346 |
Components for smoke and heat control systems - |
(D7.5) |
||
|
: Part 1: 1990 |
- Specification for natural smoke and heat exhaust ventilators |
AMD 7193 |
(D7.2) |
|
|
: Part 2: 1990 |
- Specification for powered smoke and heat exhaust ventilators |
AMD 7028 |
(E9.20) |
|
|
: Part 3: 1990 |
- Specification for smoke curtains |
AMD 6770 AMD 7029 |
(D7.2) |
|
|
BS 7435 |
Fibre cement flue pipes, fittings and terminals |
|||
|
: Part 1: 1991 |
- Specification for light quality fibre cement flue pipes, fittings and terminals |
(F6.11) |
||
|
BS 7501 |
: 1989 |
General criteria for the operation of testing laboratories |
(B2.1) |
|
|
BS 7502 |
: 1989 |
General criteria for the assessment of testing laboratories |
(B2.1) |
|
|
BS 7511 |
: 1989 |
General criteria for certification bodies operating product certification |
(B2.1) |
|
|
BS 7512 |
: 1989 |
General criteria for certification bodies operating quality system certification |
(B2.1) |
|
|
BS 7513 |
: 1989 |
General criteria for certification bodies operating certification of personnel |
(B2.1) |
|
|
BS 7514 |
: 1989 |
General criteria for suppliers declaration of conformity |
(B2.1) |
|
|
BS 7566 |
Installation of factory-made chimneys to BS4543 for domestic appliances |
|||
|
: Part 1: 1992 |
- Method of specifying installation design information |
(F3.7), (F4.11) |
||
|
: Part 2: 1992 |
- Specification for installation design |
(F3.7), (F4.11) |
||
|
: Part 3: 1992 |
- Specification for site installation |
(F3.7), (F4.11) |
||
|
: Part 4: 1992 |
- Recommendations for installation design and installation |
(F3.7), (F3.8) (F4.11) |
||
|
BS 7671 |
: 1992 |
Requirements for electrical installations, IEE Wiring Regulations, Sixteenth edition |
AMD 8536 AMD 9781 |
N Introduction, (N2.1) |
|
BS 8004 |
: 1986 |
Code of practice for foundations |
(C2.1) |
|
|
BS 8103 |
Structural design of low rise buildings |
|||
|
: Part 1: 1995 |
- Code of practice for stability, site investigation, foundations and ground floor slabs for housing |
AMD 8980 |
(C2.1) |
|
|
: Part 2: 1996 |
- Code of practice for masonry walls for housing |
(C2.1) |
||
|
: Part 3: 1996 |
- Code of practice for timber floors and roofs for housing |
(C2.1) |
||
|
: Part 4: 1995 |
- Code of practice for suspended concrete floors for housing |
(C2.1) |
||
|
BS 8104 |
: 1992 |
Code of practice for assessing exposure of walls to wind-driven rain |
AMD 8358 |
(G3.1) |
|
BS 8110 |
- |
Structural use of concrete |
||
|
: Part 1: 1997 |
- Code of practice for design and construction |
(C2.1), (C3.1) |
||
|
: Part 2: 1985 : |
- Code of practice for special circumstances |
AMD 5914 |
(C2.1), (C3.1) D Appendix |
|
|
: Part 3: 1985 |
- Design charts for singly reinforced beams, doubly reinforced beams and rectangular columns |
AMD 5918 |
(C2.1) |
|
|
BS 8118 |
Structural use of aluminium - |
|||
|
: Part 1: 1991 |
- Code of practice for design |
(C2.1) |
||
|
: Part 2: 1991 |
- Specification for materials, workmanship and protection |
(C2.1) |
||
|
BS 8200 |
: 1985 |
Code of practice for design of non-loadbearing external vertical enclosures of buildings |
(G3.1) |